Device R&D and process studies
Compare devices, layouts, processes or bias states under controlled cumulative ionizing-dose conditions.
ACCURAD TID-X INSTRUMENTS
AccuRad TID-X integrates X-ray irradiation, dosimetry, device bias, parameter measurement, software and delivery support for wafers, chips, power devices and electronic modules.

PRODUCT POSITION
Configuration starts with the device and data required, then defines irradiation, dosimetry, bias, measurement and facility conditions.
Compare devices, layouts, processes or bias states under controlled cumulative ionizing-dose conditions.
Bring dose steps, electrical or functional measurements, criteria and reporting into a repeatable internal workflow.
Support multiple device types and users through scalable fixtures, instruments and data workflows.
Coordinate equipment, methods, training and service from facility, protection and licensing boundaries.
SYSTEM ARCHITECTURE
Final models, ranges, channels and performance claims are defined together with verifiable acceptance conditions in the technical agreement.
X-ray source, sample plane, positioning, shutter, control and the required safety interlocks.
Reference medium, detector, calibration, dose records and field-uniformity evaluation.
Fixtures, bias channels, instrument interfaces, cabling and electrical measurement checkpoints.
Test configuration, system state, dose, bias, measurements, logs and data export.
TEST WORKFLOW
Connect sample information, test configuration, dose records, bias state, measurements and system logs in a repeatable, reviewable and extensible workflow.
Explore systems and laboratory integrationCONFIGURATION LOGIC
A useful comparison goes beyond one dose-rate or power number: the sample, method, data and facility must work together.
Wafers, bare die, packaged devices, board-level assemblies or electronic modules.
Process comparison, device screening, reliability study, product verification or research.
Total dose, dose rate, steps, reference medium and field-uniformity expectations.
Static or dynamic bias, channel count, limits, timing and exception handling.
Offline or in-situ parameters, instruments, sampling cadence, data volume and criteria.
Space, shielding, licensing, power, ventilation, network, logistics and maintenance.
DELIVERY AND SUPPORT
Installation is not the finish line. Methods, acceptance records, training, maintenance and later expansion determine whether the capability remains usable.
Define devices, samples, dose, bias, measurements, throughput and expected use.
Confirm the system, dosimetry, fixtures, instruments, software, interfaces and acceptance method.
Coordinate manufacturing with facility, protection, licensing, utilities and installation readiness.
Complete agreed functional and performance checks and introduce operating and application methods.
Support calibration, maintenance, refresher training, fixtures, software and application work.
Licensing and safety boundary X-ray systems avoid purchasing, transporting and replacing radioisotope sources. Production, sale and use still remain subject to applicable radiation-safety licensing, protection, monitoring and personnel-management requirements.
PROJECT INTAKE
Share a non-sensitive device range, sample size, target dose, bias, measurement needs and expected usage so we can assess application and facility boundaries.